There are two different things here:
- Robot faults are latched conditions that put the robot into
faulted(oremergency_stopped) and disable the drives. They appear in telemetry'sfaultfield. - Error codes are returned when a single request is refused. The robot's state doesn't change.
Robot faults
| Code | Detected by | Cause | Response |
|---|---|---|---|
communication_lost | MCU watchdog or engine | MCU heard nothing from the host for watchdog_ms (e.g. USB unplugged, host hung); or the engine heard nothing from the MCU for 1 s, or the stream closed | Drives disabled, queue flushed. The engine attempts to reconnect |
queue_underrun | MCU | The segment queue ran dry in the middle of a move | Drives disabled |
segment_late | MCU | A segment started too late, or the step tick stalled during motion | Drives disabled; no catch-up steps |
limit_hit | MCU | Endstop triggered while moving toward the switch | No further step; drives disabled. Reset is refused while the axis is still on the switch with no known safe direction — move it off by hand |
soft_limit | engine (planning) and MCU (per step) | Motion would leave [min, max] | Request rejected by the engine; if the MCU catches it, drives disabled |
homing_failed | MCU | No endstop trigger within max_travel | Drives disabled |
mcu_fault | MCU | Other firmware fault, e.g. StepRateExceeded on RP2040 when PIO output falls behind or a window's steps don't fit the pulse timing | Drives disabled |
plugin_failed | plugin runtime | A plugin the robot requires failed | Plugin and its dependents marked failed |
emergency_stop | engine + MCU | Software E-stop, or on RP2040 the GP27 interlock opened | Latched emergency_stopped, drives disabled |
Clearing a fault
- Remove the cause: reconnect the cable, close the interlock, move off the switch by hand with drives off, and so on.
reset-fault(CLI),POST /api/commands/reset_fault, orResetFault(gRPC).- The robot lands in
disabled(ordisconnectedif the MCU link is down). It never resumes the interrupted motion. enableand re-home every axis; faults clear the homed flag.
Every fault latched by the MCU disables all drives. Only the first fault is recorded; later faults don't overwrite it.
The MCU refuses a reset until the hazard is verifiably gone: it is refused while any drive is enabled or moving, while an endstop that caused limit_hit is still pressed, and on RP2040 while the GP27 interlock is open.
HTTP error codes
Through the ratavyr gateway, these codes are returned as HTTP statuses with a JSON error envelope. See ratavyr: error codes.
gRPC error codes
The engine returns gRPC status codes, with the precise code in the trailer motioncore-error-code:
| Code | gRPC status |
|---|---|
bad_request, validation_failed | INVALID_ARGUMENT |
unknown_axis, not_found | NOT_FOUND |
not_homed, invalid_state | FAILED_PRECONDITION |
mcu_error | UNAVAILABLE |
internal | INTERNAL |
MCU NACK reasons
Inside the MCU protocol, the firmware refuses individual frames with a NACK. These surface to clients as mcu_error or as a fault.
| Reason | Meaning |
|---|---|
UnknownAxis | Channel not configured |
QueueFull | Segment queue full |
InvalidState | Not allowed in the MCU's current state |
InvalidParams | Parameters failed validation |
SoftLimit | Would leave the soft limits |
Faulted | A fault is latched |
Busy | Axis is moving |