Skip to content

Moving axes ​

All motion commands address one axis at a time. Coordinated multi-axis moves are not available yet. A new motion command is only accepted while the robot is ready, so wait for the previous one to finish.

The same commands are available from the CLI, the REST API and the engine gRPC API:

ActionCLIREST (POST /api/commands/{name})gRPC
Energise drivesmotioncore enableenableEnable
De-energise (controlled stop first)motioncore disabledisableDisable
Home an axismotioncore home j1home {"axis":"j1"}Home
Relative movemotioncore jog j1 5 [--velocity V]jog {"axis":"j1","delta":5}Jog
Absolute movemotioncore move j1 -90 [--velocity V]move_to {"axis":"j1","position":-90}MoveTo
Controlled stopmotioncore stopstopStop
Emergency stopmotioncore estopestopEmergencyStop
Clear a faultmotioncore reset-faultreset_faultResetFault

All values are in the axis's unit: degrees for revolute axes, millimetres for prismatic ones.

A typical session ​

  1. enable → state ready.
  2. home each axis that has homing configured. The axis searches for its endstop at the homing speed and is assigned the configured home position.
  3. move or jog. Each returns as soon as the engine accepts it; watch telemetry (motioncore watch) for progress. The state is running while the axis moves and returns to ready.
  4. stop to interrupt a move with controlled deceleration, or disable to stop and de-energise.

Homed vs. unhomed ​

UnhomedHomed
jogAllowed, at 25 % of max_velocity by default, and only within one travel range of the power-on positionAllowed, default velocity max_velocity
moveRejected (not_homed)Allowed
Soft limitsRelative to an unknown originEnforced against real positions

An axis loses its homed flag on any fault or E-stop. Re-home after reset-fault.

Velocity ​

--velocity (CLI) or velocity (API) sets the cruise velocity. It is optional; the default is the axis maximum.

  • Homed axis: a velocity above max_velocity is rejected with validation_failed.
  • Unhomed axis: the velocity is capped at 25 % of max_velocity; a higher request is silently clamped to the cap.

Moves that are too short to reach the cruise velocity simply follow a triangular profile.

Positions in telemetry ​

Each axis reports:

FieldMeaning
commanded_positionWhere the planner has commanded the axis to be
measured_positionFrom the MCU's step counter. There is no encoder feedback yet, so this shows what the MCU emitted, not what the motor did
velocityCurrent velocity
homed, enabled, endstopFlags

When the MCU reports idle, commanded positions are re-synced from the MCU step counter.

When a command is refused ​

ErrorTypical cause
invalid_state (409)Robot not ready: still moving, disabled, faulted or E-stopped
not_homed (400)move on an unhomed axis
validation_failed (400)Target outside soft limits, velocity above maximum, non-finite value
bad_request (400)home on an axis without [axis.homing]
unknown_axis (404)Axis id not in the configuration
mcu_error (502)MCU rejected the request or the link failed

Full list: Faults & error codes.